| Part No.: | AP119 |
| Power Supply Type: | Electric Power Supply |
| Special Feature: | 1.For electrical equipments; 4 outputs. 2.Low standby power consumption, stable operating status, high reliability, etc. 3.With input over-voltage protection and output short-circuit/over-voltage protection, etc. |
| Input | Output | |||||
| Rated voltage | 100~240vac | Voltage | 5Vdc | 12Vdc | -12Vdc | 12Vdc |
| Voltage range | 90~264Vac | Current | 1.2A | 0.2A | 0.2A | 2A |
| Frequency | 50Hz/60Hz ± 5% | Regulation | ±3% | ±5% | ±5% | ±5% |
| Efficiency | ≥70% | Ripple and noise | ≤50mVp-p | ≤50mVp-p | ≤50mVp-p | ≤50mVp-p |
| Leakage current | ≤3.5mA | |||||
| Safety standard | ||
| Safety | IEC60950, EN60950, GB4943, EN61010-1 | |
| EMC | CE | EN55022, CLASS B |
| RE | EN55022, CLASS B | |
| Withstand voltage | |
| Input-output Withstand voltage | 3000Vac/10mA/1min |
| Input-FG Withstand voltage | 2500Vac/5mA/1min |
| Input-Signal Withstand voltage | |
| Output-FG Withstand voltage | |
| Output-Signal Withstand voltage | |
| Operating Temperature | -25℃~55℃ |
| Relative Humidity | 10%~95% |
| Storage temp. | -55℃~85℃ |
| Cooling | Natural convection |